Version: 1.0
Quick Start Guide for VigorAccess IVD
10
S How to Upgrade Firmware
Users can use the following commands to upgrade new firmware. Make sure you have prepared a TFTP
server on a host and put the firmware (ivd.all for example) in the right directory of the TFTP server
Command Description
Admin> system
Enter system directory
Admin/system> upgrade <ServIP>
<FirmName>
Execute the firmware upgrading
Admin/system> reboot
Reboot the Controller to run the new firmware
Admin/system> basicInfo
After rebooting, check the firmware version
S How to Save Configuration
Users can use the following command to save the current configuration.
Command Description
Admin> commit
Save the configuration
S How to Enable/Disable the Switch Port
Users can use the following commands to enable or disable the port on Controller. By default, G1 to G6
are off, but G0 and UP-G are on. If users find that when they connect the subtend slave machines to the
master machine but the connection cannot be constructed, check the link status of the port connected to
the master machine is enabled.
Note: Ports G1 to G6 will be on with default if the DSL F/W version is above V2.10.2.6.
Command Description
Admin> system
Enter system directory
Admin/system> link_state -s
Display the current status of all ports
Admin/system> link_state -m <IntfName>
on/off
Turn on/off of the specific port
S How to Connect to DSL Module
Users can login to DSL module in master or slave units using the following command. Once entering into
DSL module, the command described in Part II can be used.
Command Description
Admin> dsl
Display the current connectivity with DSL modules
Admin> dsl –c
Login to DSL module in master via serial channel
Admin> dsl –m
Login to DSL modules in master via Ethernet channel
Admin> dsl –s <salveId>
Login to DSL modules in slave via Ethernet channel